AFM探针Olympus导电探针AC240TM-R3 10根/盒

销售价
-
货品编号:34-803.OLY.AC240TM-R3-10
品牌:Olympus
探针数量:
10根
30根
50根
有现货
+ -
加入购物车
立即购买
商品介绍
商品评价
   

【技术参数】

 

 

型号

AC240TM

制造厂商

Olympus

探针描述

导电探针; 硅基探针;Al反射层; 针尖镀Pt

类型

电学模式

应用

导电模式;静电力模式表面电势模式;扫描电容模式;压电力模式;(CAFM; EFM; KPFM; SCM; PFM)


【产品详情】

悬臂描述

Lever

1

2

3

4

Spring k (N/m)

2 (0.3 - 4.8)

-

-

-

Freq (kHz)

70 (45 - 95)

-

-

-

Length (µm)

240 (232 - 248)

-

-

-

Width (µm)

40 (39 - 41)

-

-

-

Thickness (µm)

2.3 (1.6 - 3.0)

-

-

-

Shape

rectangular

-

-

-

Material

Silicon

-

-

-

Reflex Coating (nm)

Al (100)

-

-

-


针尖描述

Tip radius (nm)

28 +/- 10

Tip height (µm)

14 +/- 1

Front angle (°)

0 +/- 1

Back angle (°)

35 +/- 1

Side angle (°)

15 +/- 1

Tip shape

3-sided

Tip material

Silicon

Tip coating (nm)

Ti/Pt (5/20)


DESCRIPTION

f = 70 kHz   |   k = 2 N/m   |   tip coating: Ti/Pt

Each pack contains 10 probes. 

The new OMCL-AC240TM type 3 series with ‘New Concept Chip’.

Platinum-deposited cantilever is suitable for electrical characterization application such as electric force microscopy (EFM), Kelvin probe force microscopy (KFM).

OUTSTANDING FEATURES:


1. Platinum coating for electrical measurement
The platinum layer is deposited on the basic silicon probe with the titanium interfacial layer. The surfaces of precious metal coatings are free from oxidization and are electrically stable. The platinum layer on the probe has smooth surface, and the tip shape follows the shape of the basic silicon probe. Unprecedented probe sharpness of 15 nm (Nom.) in radius as a metal coated probe is worth trying in studying devices.

2. The higher conductivity even with a sharper probe
OMCL-AC240TM type3 with tip side platinum coating shows higher conductivity while its probe is sharpened more than Olympus conventional product. This probe reveals sample surface precisely both in electrically and in topographically.

3. Ideally point terminated probe
The apex of the tetrahedral probe is ideally point terminated. The tetrahedral probe shows good symmetry viewed from the front of the cantilever.

4. Acclaimed ‘TipView’ structure
The probe can be easily positioned at the exact point of your interest due to ‘TipView’ structure. The probe is located at the exact end of the cantilever so that the probe apex is not obscured during optical observations.

5. Reflex side aluminum coating
Thin aluminum film with the thickness of 100 nm is deposited on the cantilever for reflecting light from the deflection sensor in the AFM equipment. High reflex for high S/N sensing can be expected.

6. Ease in chip handling: ‘New concept chip’
The ideally vertical side-walls of the chip make tweezing easy and eliminate problems with chipping and debris.